The following table explains the most common ScanMail messages that may appear on
the Domino server console:
|
Message
|
Cause
|
What To Do
|
|
SMDreal: Unable to create message queue. Restart Domino server.
|
Domino server may not be running properly.
|
Restart the Domino server.
|
|
SMDreal: Unable to initialize common message. Unload and then reload SMDreal.
|
Message files are missing.
|
Uninstall, and then re-install ScanMail.
|
|
SMDreal: Unable to initialize scan engine. Check the scan engine and pattern file.
|
The scan engine or pattern file is missing.
smconf.nsf does not contain policy document |
Uninstall, and then re-install ScanMail.
Create a policy in
smconf.nsf, and then load smdreal again |
|
SMDreal: Missing Extension Manager in
notes.ini. Re-install ScanMail. |
ScanMail was installed using a wrong installation package. Alternatively, ScanMail
was removed manually.
|
Uninstall, and then re-install ScanMail.
|
|
SMDreal: Invalid Activation Code. Activate ScanMail via the Configuration Database
and then reload SMDreal.
|
Activation Code (AC) was not entered during ScanMail installation. Alternatively,
an invalid AC was entered.
|
Enter a valid AC using the ScanMail Configuration Database > Administration > Product License document. See Registering and Activating SMD.
|
|
SMDreal: The trial period has expired. Obtain a Registration Key and then activate
ScanMail.
|
An AC trial version was entered during installation, and the AC already expired.
|
|
|
SMDreal: Unable to load policy. Check Configuration Database and then reload SMDreal.
|
The Configuration Database might be corrupt.
|
Reinstall ScanMail.
|
|
SMDreal: Unable to load Message Database. Check
smmsg.nsf and then reload SMDreal. |
smmsg.nsf (ScanMail Message Database) might be corrupt. |
|
|
SMDdbs: Invalid database list settings. Check the database list in the Manual or Scheduled
scan rule setting.
|
The format of the database list in the Configuration Database is incorrect.
|
Check Databases to Scan list in the Real-time Database Scan, Scheduled Scan, or Manual Scan documents. Use semicolons to separate multiple entries.
|
|
SMDreal: Unable to read Domino directory. Check server status.
|
The fully qualified name (FQDN) of the Domino server is empty. Alternatively, other
Domino configuration is wrong.
|
Correct the Domino settings.
|
|
SMDreal: Cannot open database {database name}. Check the database name in the Configuration
Database.
|
ScanMail cannot open the database when trying to scan the special document in that
database. Probably, the database was deleted before ScanMail was able to scan it.
|
No action needed.
|
|
SMDdbs: Cannot read Database Scan settings. Check Configuration Database.
|
Database Scan setting is incorrect.
|
Check database scan rule (see Creating Real-time Database Scan Rules).
|
|
SMDupd: Unable to run multiple SMDupd instances
|
Scheduled update, manual update, or update task from the Apex Central / Control Manager
server are running at the same time.
|
Wait until an update is finished, then run another update task.
|
|
SMDupd: Invalid parameter
|
The Update task only accepts 4 kinds of format parameter, which represent update that
was triggered from 3 different sources. If the parameter did not follow the required
format, this message will be displayed.
|
Check the manual scan document or scheduled update rule (see Running Manual Scan or Updating Components).
|
|
SMDupd: Unable to initialize the update task
|
Unable to obtain the correct update settings or ActiveUpdate cannot be invoked.
|
|
|
SMDupd: Unable to set up connection. Check network connection. Refer to ScanMail Help
> Troubleshooting section for details.
|
Connection to the ActiveUpdate server cannot be established.
|
Check the network connection and the proxy server connection and configuration. Refer
to <ScanMail Installation Path>\AU_Log\TmuDump.txt for details.
|
|
SMDupd: Unable to download components. Check server status or refer to ScanMail Help
> Troubleshooting section for details.
|
Network congestion or unable to perform integrity checking for the downloaded component.
|
Refer to <ScanMail Installation Path>\AU_Log\TmuDump.txt for details.
|
|
SMDupd: Unable to update component(s), the Activation Code already expired.
|
AC already expired.
|
|
|
SMDupd: Unable to update to the latest version. Refer to ScanMail Help > Troubleshooting
for details.
|
Connection to the ActiveUpdate server cannot be established or
unable to perform integrity checking for the downloaded component.
|
Check the network connection and the proxy server connection and configuration.
Refer to <ScanMail Installation Path>\AU_Log\TmuDump.txt for details.
|
|
SMD Loader: The executable file exceeds the allowable maximum size {maximum size}
|
The path name of executable file is too long. This could be caused by multiple cascading
subdirectories or long file names.
|
Reinstall ScanMail on a directory with a short path name.
|
|
SMD Loader: Unable to find the latest program directory
|
Unable to find ScanMailInstallPath in
notes.ini. This is caused by incomplete installation or manual deletion of ScanMail files. |
Reinstall ScanMail or add
ScanMailInstallPath parameter and value in notes.ini. |
|
SMD Loader: Unable to browse the latest program directory {path}
|
The path name specified by ScanMailInstallPath is an invalid path or directory.
|
Reinstall ScanMail or add the correct
ScanMailInstallPath parameter and value in notes.ini. |
|
SMD Loader: Unable to load dynamic library "%s"
|
Unable to load the dynamic library because a file is missing, corrupted, or has insufficient
permission.
|
Reinstall ScanMail or obtain a valid file and overwrite the corrupted one on the Domino
server.
|
|
SMDsch: Unable to start the scheduled task "%s"
|
