To manually roll back to SMD 5.8:
-
Stop the Domino server.
-
Replace the following files with the original files that you backed up before upgrading to SMD 5.8 SP1 (see Important SMD Files to Back Up):
-
SMD data directory under Domino data path.For example:
C:\Program Files\IBM\Domino\data\smd
-
SMD binary directory.For example:
C:\Program Files\Trend Micro\ScanMail for Domino
-
The following SMD binaries under Domino binary path (for example:
C:\Program Files\IBM\Domino
):-
nSMDupd.exe
-
nsmdTools.exe
-
nSMDsupp.exe
-
nSMDsch.exe
-
nSMDreal.exe
-
nSMDmon.exe
-
nSMDext.dll
-
nSMDEUQ.exe
-
nSMDemf.exe
-
nSMDDTAS.exe
-
nSMDdbs.exe
-
nSMDcm.exe
-
-
-
Update
smdsys.ini
:-
Open
C:\Windows\smdsys.ini
in a text editor. -
Look for the section SMDConf, and change ProductVersion back to V5.8.
-
Look for the section DomSvr, and change the DomSvr0SMDVersion field back to 5.8.
-
Save and close
smdsys.ini
.
-
-
Start the Domino server.