To manually roll back to SMD 5.8:
-
Stop the Domino server.
-
Replace the following files with the original files that you backed up before upgrading to SMD 5.8 SP1 (see Important SMD Files to Back Up):
-
SMD data directory under Domino data path.For example:
C:\Program Files\IBM\Domino\data\smd -
SMD binary directory.For example:
C:\Program Files\Trend Micro\ScanMail for Domino -
The following SMD binaries under Domino binary path (for example:
C:\Program Files\IBM\Domino):-
nSMDupd.exe -
nsmdTools.exe -
nSMDsupp.exe -
nSMDsch.exe -
nSMDreal.exe -
nSMDmon.exe -
nSMDext.dll -
nSMDEUQ.exe -
nSMDemf.exe -
nSMDDTAS.exe -
nSMDdbs.exe -
nSMDcm.exe
-
-
-
Update
smdsys.ini:-
Open
C:\Windows\smdsys.iniin a text editor. -
Look for the section SMDConf, and change ProductVersion back to V5.8.
-
Look for the section DomSvr, and change the DomSvr0SMDVersion field back to 5.8.
-
Save and close
smdsys.ini.
-
-
Start the Domino server.