You can use
the Deployment Wizard to configure the basic
settings for a Multi-Bridge deployment on your Deep Discovery Web
Inspector appliance.
![]() |
ImportantTo deploy a
Multi-Bridge configuration, the appliance must be equipped with two bypass cards and
LACP must be disabled.
|
You can exit the Deployment Wizard at any
time by clicking on another menu item in the management console. If you exit the
wizard before finishing the configuration process, all data entered will be
lost.
Procedure
- Go to .The Welcome page opens.
- In the Deployment Mode section, select Transparent bridge.
- Click Next.
- In the Working Mode
Settings page, specify the following:OptionDescriptionHTTP portScan for HTTP traffic on this port. Default is 80.HTTPS portScan for HTTPS traffic on this port. Default is 443. Allow the port to be empty to bypass https traffic.
- Click Next.
- In the Network page, specify the following details:OptionDescriptionHost nameSpecify a host name.Primary DNS serverSpecify the IP address of the DNS server. This is a required setting.Secondary DNS serverOptionally, specify the IP address for a secondary DNS server.Enable LACPEnsure that LACP is not enabled.This configuration only appears when the device is configured with two bypass cards. When deployed in a Multi-Bridge configuration, LACP must be disabled.LACP bond interfaceThis option is visible only if LACP is enabled.Data ingress / egress interfaceSpecify the data ingress/egress interface.When deployed in a Multi-Bridge configuration, select two pairs of network cards as eth4/eth5 eth6/eth7.Management interfaceThis is a read-only field and is pre-set to eth0.ModeThis is a read-only field and is pre-set to static.IPv4 address, IPv4 mask, and Default IPv4 gatewaySpecify the IPv4 network settings.
- Click Next.The Time page opens.
- In the Time section,
configure the time and location settings for the Deep Discovery Web
Inspector appliance.OptionDescriptionNTP serverEnter the NTP server IP address.System time zoneSet the appropriate time zone by selecting the location closest to the Deep Discovery Web Inspector appliance.Optionally, instead of selecting a location, you can select
Etc
and then choose the offset that matches the location closest to the Deep Discovery Web Inspector appliance. - Click Next.The Summary page opens.
- Review and verify the settings and then perform the
appropriate action:
- If the settings are not as desired, click on Previous and modify settings as required.
- If the settings are verified, click on
Done to save the configuration.
Note
After you click Done, a dialog box opens asking if you want to reboot the appliance. After you click OK, the connection to the appliance disconnects and the appliance reboots. After the appliance restarts, the Log On page is displayed.If you do not want to reboot, you can click Cancel instead of OK. If you click Cancel, the Summary page reopens.
Important
If you exit the wizard before saving settings, the configuration is not saved.