Views:
Deep Discovery Inspector 6.7 SP1 can restore backup files only from versions 6.7 and 6.7 SP1. In addition, Deep Discovery Inspector can restore backup files only from Deep Discovery Inspector appliances that use the same language version.

Procedure

  1. Before importing a file, back up the current configurations. For details, see Back up file settings.
  2. Go to AdministrationSystem MaintenanceBackup / Restore.
  3. Under Restore Configuration, browse to the location of the encrypted backup file.
    The File Upload screen appears.
  4. Select the encrypted file to import and click Restore Configuration.
    A confirmation message appears.
  5. Click OK.
    Deep Discovery Inspector restarts after importing and checking the integrity of the configuration file.
    Important
    Important
    • After importing a configuration file, Deep Discovery Inspector disables Virtual Analyzer.
    • The management console password might reset if the configuration file containing password information is corrupted.
      If you cannot sign to the management console using your password, use the default password (admin) instead.
  6. To manually enable Virtual Analyzer, go to AdministrationVirtual AnalyzerSetup.