Procedure

  1. Type valid logon credentials. The default credentials are:
    • User name: admin
    • Password: Admin1234!
    Note
    Note
    None of the characters you type appear on the screen.
    This password is the same as the password used to log on to the web-based management console. For more information, see Logon Credentials.
    The Main Menu screen appears.
  2. Select Configure appliance IP address and press ENTER.
    The Appliance IP Settings screen appears.
  3. Specify the following required settings:
    Item
    Guidelines
    IPv4 address
    • Must be in the same subnet as the virtual IP address.
    • Must not conflict with the following addresses:
      • Sandbox network: Configured in Virtual Analyzer Sandbox Management Network Connection
      • Virtual IP address: Configured in Administration System Settings High Availability
      • Virtual Analyzer: 1.1.0.0/27, 1.1.2.0/24, 192.0.2.0/24, 198.18.0.0/15, 198.51.100.0/24, and 203.0.113.0/24
      • Broadcast: 255.255.255.255
      • Multicast: 224.0.0.0 - 239.255.255.255
      • Link local: 169.254.1.0 - 169.254.254.255
      • Class E: 240.0.0.0 - 255.255.255.255
      • Localhost: 127.0.0.1/8
    Note
    Note
    Changing the IP address changes the management console URL.
    Subnet mask
    Must use a standard subnet mask format
    IPv4 gateway
    Must be in the same subnet as the IP address
    IPv4 DNS server 1
    Same as IP address
    IPv4 DNS server 2 (Optional)
    Same as IP address
  4. (Optional) Configure the IPv6 settings.
  5. Press TAB to navigate to Save, and then press ENTER.