Error Code
|
Message, Cause, and Solution
|
---|---|
001
|
An error in the Plug-In Manager program
occurred.
The Plug-In Manager update
module does not respond when querying the progress of an update
task. The module or command handler may not have been not initialized.
Restart
the OfficeScan Plug-In Manager service
and perform the task again.
|
002
|
A system error occurred.
The Plug-In Manager update module is unable
to open the registry key SOFTWARE\TrendMicro\OfficeScan\service\AoS because
it may have been deleted.
Perform the following steps:
|
028
|
An update error occurred.
Possible
causes:
Perform
the following steps:
|
170
|
A system error occurred.
Plug-In Manager update module cannot process
an incoming operation because it is currently handling another operation.
Perform
the task at a later time.
|
202
|
An error in the Plug-In Manager program
occurred.
The Plug-In Manager program
cannot handle the task being executed on the Web console.
Refresh
the Web console or upgrade Plug-In Manager if
an upgrade to the program is available.
|
203
|
An error in the Plug-In Manager program
occurred.
The Plug-In Manager program
encountered an interprocess communication (IPC) error when attempting
to communicate with Plug-In Manager backend
services.
Restart the OfficeScan Plug-In Manager service
and perform the task again.
|
Other error codes
|
A system error occurred.
When downloading
a new plug-in program, Plug-In Manager checks
the plug-in program list from the ActiveUpdate server. Plug-In Manager was unable to obtain the list.
Perform
the following steps:
|