Reason
|
Action
|
---|---|
Virtual Analyzer does not support the file format, or the file is empty.
|
Check the supported file type list in the
tab.
|
The available sandbox images do not support the file format.
|
Check the sandbox image information in the
tab.
|
The URL exceeds the limit of 2083 characters.
|
Verify that the URL does not exceed 2,083 characters.
|
Virtual Analyzer does not support the encryption or compression format.
|
Check the password list in the
tab.
|
Virtual Analyzer does not support the file format.
|
Unsupported file type in current sandbox image. Check the sandbox image
information in the
tab.
|
Virtual Analyzer is unable to access the Internet.
|
Verify the connection of the management network to the Internet.
|
An unexpected error has occurred on the Sandbox for macOS.
|
Please contact your support provider.
|
The Sandbox for macOS did not return an analysis result before the timeout
period expired.
|
Resubmit the object for analysis. If the issue persists, contact your support
provider.
|
Unable to establish a connection to the Sandbox for macOS.
|
Verify the connection of the management network to the Internet.
|
The URL is invalid.
|
Verify that the specified URL is in a valid format.
|
Extracted file sizes exceeds total limitation
|
Verify that the total file size of the extracted samples do not exceed the
specified limitation.
|
Archive extracted for analysis. Child file scanning is unsuccessful.
|
See the scan results for the extracted files.
|
Virtual Analyzer is unable to analyze the object. The available disk space is
insufficient.
|
Verify that the disk space is sufficient to perform the analysis.
|
Virtual Analyzer is unable to analyze the object within the timeout
period.
|
Resubmit the object for analysis. If the issue persists, contact your support
provider.
|
Virtual Analyzer is unable to analyze the object. Dependencies that the object requires
cannot be found.
|
Missing required files to execute the application. Use the Bundle
files option to upload the required files to analyze the object.
|
Virtual Analyzer is unable to analyze the object. The object crashes while being
analyzed.
|
Resubmit the object for analysis. If the issue persists, contact your support
provider.
|
Virtual Analyzer is unable to analyze the object. The object must be run with the
correct
command line arguments.
|
Resubmit the object with the required command line parameters.
|
Virtual Analyzer is unable to analyze the object. The Office license has expired.
|
Re-import an image with a valid license for Microsoft Office.
|
An unexpected error has occurred. Please resubmit the sample for analysis. If
the issue persists, contact your support provider.
|
Resubmit the object for analysis. If the issue persists, contact your support
provider.
|
The license for the Sandbox for macOS has expired.
|
Please contact your support provider.
|